[email protected]

临床护理进展

Journal of Advances in Clinical Nursing

您当前位置:首页 > 精选文章

Journal of Advances in Clinical Nursing. 2024; 3: (2) ; 10.12208/j.jacn.20240074 .

Study on sterilization effect of hydrogen peroxide low temperature plasma sterilizer on disinfectionsupply room equipment
过氧化氢低温等离子灭菌器对消毒供应室器械的灭菌效果研究

作者: 黄冉 *

安徽省合肥市巢湖市安徽医科大学附属巢湖医院 安徽合肥

*通讯作者: 黄冉,单位:安徽省合肥市巢湖市安徽医科大学附属巢湖医院 安徽合肥;

引用本文: 黄冉 过氧化氢低温等离子灭菌器对消毒供应室器械的灭菌效果研究[J]. 临床护理进展, 2024; 3: (2) : 105-107.
Published: 2024/2/20 15:20:07

摘要

目的 分析过氧化氢低温等离子灭菌器对消毒供应室器械的灭菌效果。方法 选择2020年1月-2023年1月消毒供应室器械包一共200份,将其按照随机数表方式分组,分为对照组(n=100,环氧乙烷气体灭菌法)和观察组(n=100,过氧化氢低温等离子灭菌器灭菌),对比两组灭菌效果。结果 观察组灭菌监测合格率明显高于对照组(P<0.05)为差异显著,有统计学意义。观察组灭菌循环周期明显短于对照组,24h内器械使用率和周转率明显高于对照组(P<0.05)为差异显著,有统计学意义。观察组灭菌时间明显更短,(P<0.05)为差异显著,有统计学意义。结论 过氧化氢低温等离子灭菌器对消毒供应室器械的灭菌效果较显著,能够提高灭菌效果,提高24h内器械使用率和周转率,值得积极应用。

关键词: 过氧化氢低温等离子灭菌器;消毒供应室;灭菌监测合格率;24h内器械使用率

Abstract

Objective To analyze the sterilization effect of hydrogen peroxide low temperature plasma sterilizer on the equipment in the disinfection supply room.
Methods A total of 200 equipment kits in the disinfection supply room from January 2020 to January 2023 were selected and divided into control group (n=100, ethylene oxide gas sterilization) and observation group (n=100, hydrogen peroxide low-temperature plasma sterilization) according to a random number table, and the sterilization effect of the two groups was compared.
Results The qualified rate of sterilization monitoring in the observation group was significantly higher than that in the control group (P<0.05), indicating a significant difference with statistical significance. The sterilization cycle of the observation group was significantly shorter than that of the control group, and the utilization rate and turnover rate of instruments within 24h were significantly higher than those of the control group (P<0.05), indicating significant differences with statistical significance. The sterilization time in the observation group was significantly shorter (P<0.05), indicating a significant difference and statistical significance.
Conclusion   Hydrogen peroxide low temperature plasma sterilizer has significant sterilization effect on disinfection supply room instruments, which can improve the sterilization effect, increase the utilization rate and turnover rate of instruments within 24h, and is worthy of active application.

Key words: Hydrogen peroxide low temperature plasma sterilizer; Disinfection supply room; The qualified rate of sterilization monitoring; Device utilization rate within 24h

参考文献 References

[1] 黄永健,祝天宇,叶翠香等.过氧化氢等离子体低温灭菌器灭菌效果质量控制[J].计量与测试技术,2023,50(10): 95-97.

[2] 张建花.老肯牌LK/MJQ-100型过氧化氢低温等离子体灭菌器对腔镜器械的灭菌效果分析[J].中国医疗器械信息,2023,29(12):165-167.

[3] 吴妍,熊玲玲.过氧化氢低温等离子灭菌器在手术室中的应用及规范化管理研究[J].基层医学论坛,2023,27(12): 117-119.

[4] 杜淑贤,王晓玲,寇娟.过氧化氢等离子体低温灭菌器在消毒供应室灭菌中的应用效果[J].现代养生,2023,23(08): 587-589.

[5] 刘亚利.过氧化氢低温等离子灭菌器在手术器械灭菌质量控制中的应用[J].医学理论与实践,2021,34(17):3089-3091.

[6] 陈利,刘波,杨微等.过氧化氢低温等离子灭菌法对硬性透气性角膜接触镜试戴片的灭菌效果观察[J].第三军医大学学报,2021,43(13):1275-1279.

[7] 龙婧.过氧化氢低温等离子灭菌与传统灭菌效果方法比较[J].中国医疗器械信息,2020,26(20):46-47.

[8] 廖微.过氧化氢低温等离子体灭菌器对腔镜器械的灭菌效果[J].医疗装备,2020,33(16):51-52.

[9] 黎瑞仪,林冬梅,冯美娟等.低温等离子灭菌器对输尿管镜灭菌效果的应用探讨[J].黑龙江中医药,2020,49(03): 79-80.

[10] 丁海霞.过氧化氢低温等离子体灭菌器对腔镜器械的灭菌效果分析[J].黑龙江医药科学,2022,45(03):120-121.