Ac discussion on grounding of Transformer Core and clamp
变压器铁芯、夹件接地问题交流探讨

作者: 张军柱 *

陕西送变电工程有限公司 陕西西安

*通讯作者: 张军柱,单位:陕西送变电工程有限公司 陕西西安;

引用本文: 张军柱 变压器铁芯、夹件接地问题交流探讨[J]. 电气工程与自动化, 2022; 1: (5) : 24-28.
Published: 2022/12/23 16:54:08

摘要

变压器铁芯、夹件的接地方式,直接关系到变压器的安全运行。近几年发现很多变电站变压器铁芯、夹件的接地是与油箱壳体绝缘引下至主接地网,改变了过去经油箱下部专用接地点接地的方式。本文通过对变压器铁芯、夹件的结构、功能分析,以及探讨两种不同接地方式下对变压器安全运行的影响,从而明确与油箱绝缘引下至主接地网的方式将影响变压器的安全运行;正确的接法应该是铁芯、夹件经油箱下部专用接地点接地。

关键词: 变压器;铁芯;夹件;接地方式

Abstract

The grounding mode of transformer core and clamp is directly related to the safe operation of transformer. In recent years, many transformer cores have been found in substations, and the grounding of the clamps is caused by insulation from the oil tank shell to the main grounding grid, which has changed the way of special grounding through the lower part of the tank. In this paper, the structure and function of transformer core and clamp are analyzed, and the influence of two different grounding modes on the safe operation of transformer is discussed. Thus, it is clear that the way of insulation from the oil tank to the main ground grid will affect the safe operation of the transformer; The correct connection method should be the iron core, the clamp through the lower part of the special contact point grounding.

Key words: transformer; core; clamp; Grounding mode

参考文献 References

[1] 王越明 王朋  杨莹 变压器诊断与维修  化学工业出版社 2008.8

[2] 冯超 电力变压器检修与维护  中国电力出版社 2013.3

[3] 钟洪壁 高占邦 王正官 王世阁 电力变压器检修与试验手册  中国电力出版社 2000.1 

[4] GB 50148-2010 《电气装置安装工程 电力变压器、油浸电抗器、互感器施工及验收规范》 中国计划出版社 2010.10